Customization: | Available |
---|---|
Condition: | New |
Certification: | API, ISO, CB, CE |
Still deciding? Get samples of US$ 98/Piece
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Safe Marks | Implication |
Danger |
If ignoring safety warning, it will lead to serious accident |
Warning |
If ignoring safety warning, there is a risk of serious injury accident, serious damage to equipment |
Notice |
If ignoring safety warning, there is a risk of moderate equipment damage or partial business interruption |
State |
It means the content is additional information |
Warning ! JND-X solar controller: all installation operations must be performed by professional technicians.The professional technical personnel must go through the special training, read the manual completely and master the operation related safety matters. The company shall not be liable for any injury caused by non-professional installation operation. Failure to install and operate the controller according to the instructions in this manual will not be covered by our warranty. |
Attention ! When getting product,check whether the JND-X controller is damaged during transportation . If you find any problem, please contact the company or the transportation company immediately. |
Warning ! JND-X controller damage or other losses caused by the following circumstances will not be covered by our warranty. When the photovoltaic array is configured, ensure that the maximum short-circuit current of the dc side is within the allowable range of jnd-x controller, otherwise it may cause non-recoverable damage of . When the photovoltaic array is configured, it is important to ensure that the open circuit voltage of each photovoltaic cluster string does not exceed the maximum input range of the jnd-x controller, otherwise it will cause non-recoverable damage to the jnd-x controller. The charging current of the selected controller should not be greater than 0.3 times the battery capacity. If it is greater than 0.3 times the battery capacity, the battery will be damaged or the battery life will be reduced. Improper installation environment of jnd-x controller will affect machine performance and may cause machine damage. Do not install the jnd-x controller in flammable or explosive places or storage places for flammable or explosive materials. Do not install the JND-X controller in an explosive location. Do not install the JND-X controller where lightning strikes may occur. Do not install the JND-X controller in a place with a lot of salt spray. The controller should be well ventilated when running. JND-X controller shall be installed in an upright position and shall ensure the air duct and other non-blocking conditions. |
Attention ! All electrical installations must comply with local and national electrical installation standards. To ensure safe operation, proper grounding, proper conductor size and necessary short circuit protection are required. The connection cable must choose the suitable specification, the connection is firm and the insulation is good. After installation, check whether all wiring connections are tight to avoid the danger of heat accumulation caused by false connections. |
Danger! Do not open the machine cover plate when is charged! |
Danger! Maintenance work shall be carried out by professional maintenance technicians. The machine needs to be cut off before maintenance. After the cut off, wait 5 minutes before dismantling the machine. |
NO. | Name | Function | Explain |
1 | L+ | Connect dc load positive pole | The battery provides energy to the external dc load through the controller |
2 | L- | Connect dc load negative pole | |
3 | S1+ | Connect the positive pole of pv array 1 | PV array main input (pv array wiring priority main access) |
4 | S1- | Connect the negative pole of pv array 1 | |
5 | S2+ | Connect the positive pole of pv array 2 | Photovoltaic array auxiliary input |
6 | S2- | Connect the negative pole of pv array 2 | |
7 | B+ | Connect the battery positive electrode | Battery terminal |
8 | B- | Connect the battery negative electrode | |
9 | PE | Connect ground | Controller safe ground |
10 | RS485 | Communication port | Realize the upper computer, WIFI and GPRS communication monitoring |
11 | Circuit breaker | Battery switch | Controller starts and works normally |
12 | Display | Display screen and buttons | Display and set various parameter information of the controller |
No. | Model | L(mm) | D(mm) | H(mm) | W(kg)Ref |
1 | JND-X | 405 | 280 | 132 | 8.4 |
Attention ! When installing JND-X,ensure good air circulation around equipment. Do not install in closed boxes. |
|
Danger ! Explosion danger!Do not install the controller and battery in the same confined space!Do not install in a confined space where battery gas can accumulate. |
Note:for installation safety, we recommend a wiring sequence; Note:JND-X designed with a common negative electrode; |
Warning:Do not connect the load end to the electrical equipment that exceeds the surge power of the controller to prevent damage to the controller! Warning: make sure all wires are fixed when you need to move them around. Virtual connections can cause heat buildup, which can lead to fire |
Warning:All switches must be disconnected in the process of wiring, pay attention to the difference between positive and negative wires;The metal part of the cable terminal should not be exposed too long to prevent short circuit fault caused by contact with the housing after installation. It is strictly forbidden to connect the battery with positive and negative conductor short circuit, and it is strictly forbidden to connect the photovoltaic array to the battery terminal post, please be careful to operate. |
Warning:1,Electric shock danger!Photovoltaic modules can generate high voltages, so be careful not to shock when wiring.Please ensure that the solar panel voltage in the system does not exceed the maximum input voltage range of the controller. |
Note:PV 1 is the main road, and pv 2 is the auxiliary road. PV 1 must be connected to PV array first; |
Warning:Please switch on the power in strict accordance with step 5, otherwise there will be the risk of burning down the controller. |
electrical parameters | note | |||||||||
Rated system vol | 240V | 220V | 192V | 120V | 110V | 96V | 48V | 24V | 12V | |
Max. PV VOC | 430V | 430V | 384V | 240V | 220V | 192V | 96V | 48V | 24V | |
Min.PV working vol | 300V | 275V | 240V | 150V | 138V | 120V | 60V | 30V | 15V |
Current rate | 50A | 100A | 150A | 200A |
Wire diameter/mm2 | 10 | 20 | 30 | 40 |
AWG | 7 | 4 | 2 | 1 |
NO. | Indicator light | state | define |
1 | Trouble light ERROR(red) | put out | normal operation, no fault events |
2 | normal on | faulty event | |
3 | Charging light CHARGE(yellow) | put out | no charging |
4 | normal on | fast charging | |
5 | slow flashing | float charging | |
6 | fast flashing | boost charging | |
7 | dual scintillation | equalizing charge | |
8 | Loading light LOAD(green) | Normal on | output normal |
9 | Put out | close dc loading | |
10 | flashing | battery overdischarge off load |
Key | Function | Note |
SET | function one:main menu,function two:save key for parameter setting | Undervoltage (Under), undervoltage recovery (under-r), overvoltage (OVD), overvoltage recovery (ovd-r), floating charge (float), lifting charge (BCV), balanced charge (ECV); |
ESC | exit setting interface key; | In any parameter setting interface, press exit (ESC) button to exit the setting interface and return to standby interface; |
UP | function 1: display parameters page turning, function 2: parameter setting plus; | Function 1: the display rotates between V battery, V PV, I charge, and I Load to display corresponding real-time data;See figure 4-2 below, function 2 refer to "4.4 setting operation"; |
DOWN | function 1: display parameters to turn pages; function 2: parameter setting to reduce; |
Name |
Define |
Function |
day | The icon lights up for daytime | |
night | The icon lights up for night | |
panel | The icon lights up to check the pv array access | |
battery | The icon lights up to indicate battery access, and the inside indicates battery power | |
load | Load lit means load has output | |
state | The icon lights up and scrolls to indicate charging and discharging states, respectively | |
error | The ICONS flicker to indicate that there is a fault in the system |
Name | Define | Function |
V battery | Battery vol | Display the current battery voltage in the data display area |
VPV | Panel vol | Display the current solar panel voltage in the data display area |
I charge | Charging current | Display the current battery charging current in the data display area |
I load | Discharging current | Display the current battery discharge current in the data display area |
Under | Under voltage | Set the over discharge voltage of the battery. This field flashes when the battery is under voltage |
Under-R | Under-recover | Set the return voltage of battery over discharge |
OVD | Over voltage | Set the battery overcharge voltage, when the battery over voltage field flashing |
OVD-R | Over-recover | Set the battery over voltage return voltage |
Float | Float charging | Set the floating charge voltage of the battery, and in the floating charge stage, the field flashes |
BCV | boost charging voltage | Set the battery lifting charging voltage, and in the lifting charging phase, this field flashes |
ECV | Equalizing charge | Set the battery equalizing charging voltage, and in the equalizing charging phase, this field flashes |
MPPT | Charging ways | Represents the current solar panel array charging at maximum power |
Error | Error indicator | This field lights up when something goes wrong |
Note |
PC or APP (WIFI or GPRS mode) are optional accessories. Only one mode can be used for single communication of the device, and several communication modes cannot be used at the same time! |
Protection | Explain |
Reverse polarity connection of solar panel modules | When the polarity of solar panel modules is reversed, the controller will not be charged and will not be damaged. After correcting the wiring errors, the controller will continue to work normally |
PV over voltage protection | When solar panel array charging voltage exceeds the controller's rated input voltage range, it will stop charging |
Reverse polarity of battery | When polarity of the battery is reversed, the controller will not work and will not be damaged |
Battery over discharge protection | When battery voltage is lower than the set under voltage value, the battery will automatically stop the discharge, prevent the battery from excessive discharge and damage |
Battery overvoltage protection | When battery voltage reaches the set value of over voltage protection, it will automatically stop charging the battery to prevent the battery from overcharging and damage |
Night protection | At night, as the battery voltage is larger than the solar panel module voltage, automatic protection prevents the battery voltage from discharging through the solar panel module |
Equipment overheating protection | There is a temperature sensor inside the controller. When the temperature is higher than the set value, the charging will stop, and the temperature will automatically start and continue to work |
High voltage surge | This controller can only protect high-voltage surges with low energy. In areas with frequent lightning, it is recommended to install external lightning arrester |
Error | Indicator status and alarm icon | Possible reasons | Solutions |
Array over voltage | Red light, Icon flash |
number of photovoltaic array series groups is relatively large | Disconnect the photovoltaic array, reduce the number of photovoltaic array groups in series, and ensure that the open circuit voltage of the photovoltaic array does not exceed the set value in the "photovoltaic electrical parameters" table |
Battery over voltage | Red light,OVD and Icon flash | 1.Overvoltage protection point of the controller is lower than the maximum value of the charging range; 2.Aging or over-discharge of battery;3. Battery overdischarge; 4.Large dynamic change of load |
1. Reset the overvoltage protection point of the battery by pressing the key of the device or PC upper computer or APP; 2. Aging battery needs to be replaced; 3. Overdischarge requires manual setting of battery voltage level; 4. Reduce large dynamic changes of load; |
Battery undervoltage | Under and icon flash | battery voltage value is lower than the set value of undervoltage protection | 1. Reduce or disconnect the load. If the alarm is cancelled, the battery voltage returns to normal, indicating that the load power is too large or the battery voltage and capacity are too low. 2. When the load controller is disconnected, it still gives an alarm. The battery voltage has not recovered to the set value of overdischarge recovery. |
indicator light does not shine, the display screen does not show | battery voltage is lower than the equipment starting voltage | Use a multimeter to test whether the voltage at both ends of the battery is lower than 7V; The battery group needs to be charged by other means to make its battery voltage reach more than 8V; |
|
Radiator overheating | Red light, icon flash |
1.High ambient temperature, poor heat dissipation of equipment, and poor fan ventilation;2. The fan is damaged |
1.Check the installation environment of the equipment, remove sundries in the air duct of the equipment, and ensure the smooth ventilation of fans;2. Replace the fan when the fan is damaged; |
Charging flow | Red light,Icharge flash,icon flash | Charging over current protection check current detection abnormal, wrong operation | Restart several times if still can not be solved, need to return to the factory for maintenance |
Load flow | Red light,icon flash | High load power | 1. Reduce load power; 2. Restart and remove the fault; 3. No excessive sensibility and capacitive load; |
Note:In addition to the battery voltage can not start, other faults can be referred to the PC background or mobile APP fault information; |
Note:Electric shock risk! ! ! Make sure all the power supply of the controller is disconnected before checking or operating accordingly! |
Electrical specifications | ||||||||||
Description | Detail Specification | Note | ||||||||
Rated system voltage | 240V | 220V | 192V | 120V | 110V | 96V | 48V | 24V | 12V | |
Max. Charge current(*N) | 50A | 50A | 50A | 50A | 50A | 50A | 50A | 50A | 50A | N=1/2/3/4 |
Max.PV input power(*N) | 12000W | 11000W | 9600W | 6000W | 5500W | 4800W | 2400W | 1200W | 600W | |
Battery Max input voltage | 320V | 293V | 256V | 160V | 147V | 128V | 64V | 32V | 16V | |
Max. PV VOC | 430V | 430V | 384V | 240V | 220V | 192V | 96V | 48V | 24V | |
Min.PV working voltage | 300V | 275V | 240V | 150V | 138V | 120V | 60V | 30V | 15V | |
Static loss* | <0.2A | |||||||||
Charging circuit voltage drop | ≤0.5V | |||||||||
Discharge loop voltage drop | ≤0.3V | |||||||||
Battery terminal control parameters(Temperature:25ºC)(Factory default data) |
Rated system voltage | 240V | 220V | 192V | 120V | 110V | 96V | 48V | 24V | 12V | |
Overvoltage disconnect voltage(OVD) | 320V | 293V | 256V | 160V | 147V | 128V | 64V | 32V | 16V | |
Overvoltage disconnect recovery voltage(OVD-R) | 300V | 275V | 253V | 248V | 127V | 111V | 56V | 28V | 14V | |
Equilibrium voltage(ECV) | 294V | 270V | 235V | 147V | 135V | 118V | 59V | 29V | 14.7V | |
Boost charge voltage(BCV) | 288V | 264V | 230V | 144V | 132V | 115V | 57.6V | 28.8V | 14.4 | |
Float charge voltage (float) | 276V | 253V | 221V | 138V | 127V | 110V | 55.2V | 27.6V | 13.8 | |
Undervoltage disconnect voltage(under) | 216V | 198V | 173V | 108V | 99V | 86.4V | 43.2V | 21.7V | 10.8 | |
Undervoltage disconnect recovery voltage(under-R) | 250V | 229V | 200V | 125V | 115V | 100V | 50V | 25V | 12.5 | |
Equilibrium duration | 2 H | |||||||||
Boost duration | 2 H |